重慶申歐通訊科技有限公司客服在線留言系統(tǒng),為企業(yè)用戶提供業(yè)務(wù)咨詢、技術(shù)咨詢、售后服務(wù)等留言......申甌重慶客服留言系統(tǒng)
申甌通信重慶主頁 收藏申甌通信

申甌通信重慶微信公眾號

申甌通信重慶微博官網(wǎng)

申甌通信重慶手機版

當(dāng)前位置:留言首頁 >> 產(chǎn)品留言 >> 技術(shù)留言 >> 發(fā)布留言         留言類別:一般留言  >>  Ultra modular electronic PABX            閱讀2325次

 

Ultra modular electronic PABX(一般留言)            本頁閱讀2325次
姓名: Keen
QQ: 322355***
電話: 81627****
來自: 91.236.74.6
郵箱:
時間: 4/25/2019 12:03:03 PM
備注: "*"表示已保密
The required network shall consist (10) stations (BIA1, BIA2, IT1, K2, AJEEL FIELD, IT1A, IT2, IT2A, AZ & MS).
The system configuration of each station will be as follows:-
Equipments at above site to be installed inside an existing building, the system shall include Fiber Optic Cables, Fiber Optic Transceivers, Multiplex system, Router, LAN, Switch, G.SHDSL modems, MDF, UPS & Batteries.
PABX & DECT system is required for the above sites except BIA1 and BIA2.
Electrical power source (220 VAC/50 Hz) is available.

Ultra modular electronic PABX, software controlled and equipped with the following SPECIFICATIONS:
1-Q-SIG Networking.
2-Subscriber Groups Remoting.
3-DECT.
4-PABX must be fully redundant and resilient (power supply, call controller,…etc).
5-Remote sites should be equipped with remote shelves instead of separate PBX systems, in order to facilitate management. However, each remote shelve must be capable of having full survivability options. This means, when connection to the main PABX is lost, all features must remain supported, including management of the system.
6-PABX systems should be able to connect analog CO trunk, E1-trunk.
7-Centralized management of all systems.


4.1 The system contains:-

Main side located at ( IT1) with following specifications and capacity :-
- 500 Extension lines expandable for 800 extension lines with line impedance (2000 Ω).
- Ports:
1- E1
2- FE
3- GE
4- RS232 serial port
- 20 trunk line.
- 24 TIE line E&M wire.
- Duplicated common control part.
- Duplicated UPS with back up batteries sufficient for 48 hour
autonomy.
- Line identifier.
- Call metering pulse detector at 12/16 KHZ.
- MDF with capacity 1000/1000 provided with protection.
- Power Supply: -32 -72 VDC and / or 220 VAC.


4.2 Remote side (with stand alone facilities) located at (IT1A, IT2, and IT2A & MS).
- 100 Extension line expandable for 250 extension lines.
- Ports:
1- E1
2- FE
3- RS232 serial port
- 16 Trunk line.
- 16 TIE line E&M wire.
- Duplicated common control part.
- Duplicated UPS with back up batteries sufficient for 48 hour autonomy.
- MDF with capacity 100/100 provided with protection.
- Power Supply : -32 -72 VDC and / or 220 VAC. NOS

4.3 Stand alone PBX located at (K2).
- 100 Extension line expandable for 250 extension lines.
- Ports:
1- E1
2- FE
3- RS232 serial port
- 16 Trunk line.
- 16 TIE line E&M wire.
- Duplicated common control part.
- Duplicated UPS with back up batteries sufficient for 48 hour autonomy.
- MDF with capacity 100/100 provided with protection.
- Power Supply : -32 -72 VDC and / or 220 VAC. NOS


ITEM NO. DESCRIPTION & SPECIFICATIONS UNIT QTY. NOTES
4.4 Stand alone PBX located at (AZ, Ajeel field).
- 250 Extension line expandable for 500 extension lines.
- Ports:
1- E1
2- FE
3- RS232 serial port
- 16 Trunk line.
- 16 TIE line E&M wire.
- Duplicated common control part.
- Duplicated UPS with back up batteries sufficient for 48 hour autonomy.
- Line identifier
- Call metering pulse detector at 12/16 KHZ
- MDF with capacity 600/600 provided with protection.
- Power Supply: -32 -72 VDC and / or 220 VAC.


4.5 DECT System located at IT1, Ajeel field , K2 , IT1A , IT2 , IT2A , AZ and MS sites with following requirements:-
No of Base Stations / Site : 5
No of Handheld Terminals / Site : 8 ( intrinsically save. heavy duty suitable for explosion risk area, protection against water, protection against dustproof, emergency call key, vibration alarm, low battery warning tone & full duplex hands-free talking ).
Less cost rout digit access point (Rooming ).
Refer to (PABX & DECT SYSTEM LAYOUT).

SET

9
4.6 Network management system for controlling and monitoring the main and Remote sites (IT1A, IT2, IT2A and MS) located at (IT1). SET 1  

      Ultra modular electronic PABX-留言信息評價

 

Copyright 2006-2025 申甌通信設(shè)備有限公司旗下:重慶申歐通訊科技有限公司  重慶坤歐科技有限公司 渝ICP備09000982號-4

023-63718687

137.175.82.120歡迎訪問!::ip1:ip2:137.175.82.120 . www.glass10.cn       

主站蜘蛛池模板: 人妻少妇被猛烈进入中文字幕| 婷婷精品国产亚洲av在线观看| 亚洲色欲色欲综合网站| youjizz丰满熟妇| 色护士极品影院| 四虎国产精品永久在线| 特大巨黑吊xxx| 欧美超级乱婬视频播放| 国产无吗一区二区三区在线欢| 丰满少妇大力进入av亚洲| 欧美性猛交╳xxx乱大交| 欧美牲交黑粗硬大| 天堂网www中文在线| 久久男人av资源站| 国产精品国产三级国产aⅴ下载| 韩国电影办公室免费| 国产精品女同久久久久电影院| 野花日本大全免费观看6高清版| 夫前人妻被灌醉侵犯在线| 丰满少妇大力进入av亚洲| 国产二级一片内射视频插放| 欧美激情黑人极品hd| 三级4级全黄| 欧美精品videofree| 亚洲精品无码aⅴ中文字幕蜜桃 | 亚洲乱亚洲乱妇50p| 孕交videosgratis孕妇性欧美| 国产欧美日韩精品丝袜高跟鞋| 特级欧美aaaaaa片| 女人高潮被爽到呻吟在线观看| 日韩欧美aⅴ综合网站发布| 少妇爽到呻吟的视频| 国产肥白大熟妇bbbb视频| 久久久国产精品黄毛片| 国产精品女同一区二区| 亚洲av无码乱码国产麻豆穿越 | 另类 专区 欧美 制服丝袜| 国产久热精品无码激情| 日韩av无码免费播放| 天堂在线中文网www| 久久久久久久久无码精品亚洲日韩|